梯形钢屋架课程设计
目录
一、设计资料....................................................................................2二、屋架尺寸及结构形式与选型...................................................2三、荷载计算..................................................................................31.永久荷载....................................................................................32.可变荷载....................................................................................33.荷载组合....................................................................................4四、内力计算....................................................................................4五、杆件设计....................................................................................61.上弦杆........................................................................................62.下弦杆........................................................................................73.斜腹杆........................................................................................84.竖杆............................................................................................9六、节点设计..................................................................................101.下弦节点C..............................................................................102.上弦节点B..............................................................................113.屋脊节点G..............................................................................124.支座节点A..............................................................................13附录:钢屋架施工图
梯形钢屋架课程设计计算书
一、设计资料:
1、车间柱网布置:长度90m;柱距6m;跨度21m2、屋面坡度:1:10
3、屋面材料:预应力大型屋面板4、荷载
1)静载:屋架及支撑自重0.35KN/m²;屋面防水层0.4KN/m²;找平层0.4KN/m²;大型
屋面板自重(包括灌缝)1.4KN/m²。2)活载:屋面雪荷载0.35KN/m²;积灰荷载标准值1.2KN/m屋面活荷载标准值:
2
0.7kN/m2
5、材质
Q345B钢,焊条E50XX系列,手工焊。
荷载名称
三毡四油(上铺绿豆沙)防水层
水泥砂浆找平层
保温层
永久荷载
一毡二油隔气层水泥砂浆找平层预应力混凝土屋面板
屋架自重屋面活荷载标准值
可变荷载6、
积灰荷载雪荷载
荷载标准值(KN/m2)
0.40.40.70.050.31.4
0.12+0.11x21=0.351
0.71.200.35
荷载类型
二、结构形式与选型
屋架形式及几何尺寸如图所示
上弦横向水平支撑一般设置在房屋两端且间距不宜大于60m,根据厂房长度(90m>60m)、跨
度及荷载情况,设置上弦横向水平支撑3道。
下弦横向水平支撑与上弦横向水平支撑对应的布置在同一柱间距内,以形成稳定空间体系。
下弦纵向水平支撑不进行布置。
垂直支撑设置在上、下弦横向支撑的柱间内,在屋架两端及跨中的竖直面内。系杆沿房屋纵向通长设置,以保证屋架的侧向稳定。
三、荷载计算
屋面雪荷载与检修荷载不会同时出现,计算时,取较大的荷载标准值进行计算。故取屋面活荷载0.7KN/m²进行计算。
屋架沿水平投影面积分布的自重(包括支撑)按经验公式gk(0.120.011l)kN/m计算,跨度单位为米(m).
屋架沿水平投影面积分布的自重(包括支撑)按经验公式gk(0.120.011l)kN/m计算,跨度单位为米(m)
荷载计算表
荷载名称
预应力混凝土大型屋面板自重
屋架及支撑自重屋面防水层
标准值(KN/m²)
1.40.350.4
22
设计值(KN/m²)1.4×1.35=1.890.264×1.35=0.35640.4×1.35=0.54
找平层永久荷载总和屋面活荷载积灰荷载可变荷载总和
1、全跨永久荷载F1+全跨可变荷载F2
0.42.4640.71.21.9
0.4×1.35=0.54
3.32640.7×1.4=0.981.2×1.4=1.68
2.66
设计屋架时,应考虑以下三种荷载组合:
全跨节点永久荷载及可变荷载:
F=(3.3264+2.66)×1.5×6=53.8776kN2、全跨永久荷载F1+半跨可变荷载F2
全跨节点永久荷载:
F1=3.3264×1.5×6=29.9376kN半跨节点可变荷载:
F2=2.66×1.5×6=23.94kN
3、全跨屋架(包括支撑)自重F3+半跨屋面板自重F4+半跨屋面活荷载F2
全跨节点屋架自重:
F3=0.3564×1.5×6=3.2076kN半跨节点屋面板自重及活荷载:F4=(1.89+0.7)×1.5×6=23.31kN
1、2为使用节点荷载情况,3为施工阶段荷载情况。
四、内力计算
屋架在上述三种荷载组合作用下的计算简图如下:
2/21/2
(a)
F2/1F/(b)
/
2
F2
/2F4/2F3/2(c)
F4/23/2
由图解法或数解法解得F=1的屋架各杆件的内力系数(F=1作用于全跨、左半跨和右半
跨)。然后求出各种荷载情况下的内力进行组合,计算结果如下表:
屋架构件内力组合表
杆件名称
内力系数(F=1)全跨1
左半跨2
右半跨3
第一种组合
第二种组合F1×1+F2×2
F1×1+F2×3
第三种组合F3×1+F4×2
F3×1+F4×3
计算杆件内力(kN)
F×1
上AB弦BC、杆CD
DE、EFFG、GH下Ac弦杆
ce
eggh斜aB腹杆Bc
cDDeeFFggH
0-7.472-11.262-12.184.1009.74411.96211.768-7.6845.808-4.4092.792-1.5720.3280.713-0.5-1.0-1.0-1.0
0-5.310-7.339-6.8613.0106.6637.3265.884-5.5413.960-2.5331.222-0.047-1.0391.913-0.5-1.0-1.0-1.0
0-2.162-3.923-5.3191.0903.0814.6365.884-2.0431.848-1.7761.570-1.5251.367-1.2000000
0-402.569-606.763-656.222220.8957524.977644.477634.0245-413.991312.918-237.5437150.4246-84.694617.671738.4143-26.9358-53.877-53.877-53.877
0-350.8385-512.6406-528.9215194.8134451.2476533.5267493.197-362.7104268.6939-192.6455112.8472-48.1909-15.053467.1444-26.94-53.8776
-53.8776
-53.8776
0-275.4754-431.2685-492.0061148.8486365.4945469.1281493.197-278.9683218.1326-174.5229121.1783-83.574242.5463-7.3808-14.97-29.9376
-29.9376
-29.9376
0-147.7463-207.2006-199.003483.3159186.5733209.1432174.9077-153.811110.9397-73.188337.4415-6.1379-23.166946.8793-13.2588-26.5176-26.5176-26.5176
0-74.3664-127.5736-163.059338.5607103.0769146.4393174.907772.272661.709-55.5427
45.5534
-40.5901
32.917-25.6847
0-402.569-606.763-656.222220.8957524.977644.477634.0245-413.991312.918-237.5437150.4246-84.694642.546367.1444-26.9358-53.877-53.877-53.877
坚Aa杆
CcEeGg
-3.2076-3.2076-3.2076-3.2076
五、杆件设计
(1)上弦杆
整个上弦采用等截面,按FG杆件的最大设计内力设计,即N=-656.222KN上弦杆计算长度:
在屋架平面内:为节点轴线长度:
l0x=l0=1.508m
在屋架平面外:本屋架为无檩体系,并且认为大型屋面板只起到刚性系杆作用,根据支撑布置和内力变化情况,取l0y为支撑点间的距离,即:
l0y=3×1.508=4.524m
根据屋架平面外上弦杆的计算长度,上弦截面选用两个不等肢角钢,短肢相并。如右图:
腹杆最大内力N=-413.991KN,中间节点板厚度选用10mm,支座节点板厚度选用12mm
设λ=60,查Q345钢的稳定系数表,可得φ=0.732(由双角钢组成的T形和十字形截面均属于b类),则需要截面积为
N656.222×103
A==2891.865mm2
φf0.732×310
需要回转半径:
l1.508
m=25.1mmλ60l0y4.524iy=m=75.4mm
λ60ix
查表选用2└100×63×10
验算
a=10mm
λxλy
l1508m=65.6mmix23.0l0yiy
3016
m=40mm75.4
满足长细比[]150的要求,查表φx=0.714,则
N656.222103
=297.11MPa
故所选截面合适。(2)下弦杆
整个下弦采用等截面,按cd杆件的最大设计内力设计,即N=644.477KN
下弦杆计算长度:lox=3000mm, loy=20700/2=10350mm下弦截面选用两个不等肢角钢,短肢相并。所需截面面积:A=
N644477 ==2078.95mm2f310
查表选用2└
100×80×6,a=10mm
即A=21.274cm20.785cm,ix2.40cm,iy4.69cm,且
2
2
x=
l300
==125
=
1035
=220.68
满足要求。
y=
(3)腹杆
①aB杆:
计算长度:lox =loy=2530mm杆件轴力:N=-413.991KN因为lox =loy,选2└140×90×10所需面积:A=
N413991==3469.441mm2则A=36.078cm , ix=2.59 ,iy=6.73
2
x=97.838 ,y=37.652 ,x=0.675N252570==137.2Mpa
(4)竖杆①竖杆Gg:
杆件轴力:N=-53.877KN
计算长度:lox=0.8l=231.2cm loy=l=289cm内力较小
按[λ]=150选择
需回转半径:ix
l231.21.54cm150iy=1.93cm
A=10830mm2
查表选用2└45×4
2
a=8mm
即A=10.83cm , ix=1.72cm , iy=2.69cm且x=lox/ix=231.2/1.72=134.42
y=loy/iy=289/2.69=107.43
屋架杆件截面选择表
计算长度
cm
内力(KN)
截面规格
回转半径(cm)
计算应力
NφyA
长细比
杆件名称
杆件编号
l0xl0y
截面面积(cm²)
容许长细比
稳定系数
ixiy
λxλy
[λ]
150.00350.00150.00150.00350.00150.0
φXφy
或N/A(N/cm²)15.12731.007.209
上弦下弦
FGGHegAaaBBcCc
-656.222644.477-26.936-413.991312.918-53.8
150.[**************]3
452.[1**********]261.3229
2└160×110×142└100×80×62└56×52└140×90×102└100×
62└56×5
58.2320.79010.8344.52223.8610.83
2.822.851.724.473.11.7
7.757.702.693.664.442.6
53.48105.26115.756.6067.42106.5
58.37134.4273.9869.1358.8585.3
0.745_0.345
0.661-0.392
-_
斜腹
14.06713.11512.69
77
cDDeEeeF
竖杆
FgGggH
-237.544150.425-53.877-84.69542.546-53.87767.144
.2229.1229.1207.2249.9249.9231.2271.2
286.4286.4259312.4312.4289339
2└100×62└100×62└56×52└100×
62└56×52└56×52└100×6
23.8623.8610.8323.8610.8310.8323.86
23.13.11.723.11.721.723.1
94.444.442.694.442.692.694.44
173.979.3120.4780.61145.29134.4287.84
64.564.596.2870.36116.13107.4376.35
0150.00350.00150.00150.00350.00150.00150.00
0.3220.568-0.2670.517
-0.621
116.0326.30415.456.24939.29318.6485.443
六、节点设计
(1)下弦节点
用E50型焊条角焊缝的抗拉和抗压、抗剪强度设计值ff=200MPa。
1下弦节点“c”
w
设“Bc”杆的肢背hf=8mm和肢尖焊缝为hf=6mm.所需的焊缝长度为
肢背:lw
'
0.7N0.7312918
mm,取140mm。
2heff20.78200
0.3N0.3312918
=55.878mm,取90mm。w
2heff20.76200
肢尖:lw
''
“Cc”杆内力很小,杆的肢背hf=6mm和肢尖焊缝为hf=6mm.按构造要求综合取节点板尺寸360mm×460mm
下弦与节点板连接的焊缝长度为46cm,hf=6mm。焊缝所受的力为左右两下弦杆的内力差ΔN=304.08KN,受力较大处的肢背出的焊缝应力为:
τf
0.75304080
103.58MPa
焊缝强度满足要求。
焊缝强度满足要求。
2)上弦节点“B”
“Bc”杆与节点板的焊缝尺寸同上。NaB=-413.991kN
设“aB”杆的肢背和肢尖焊缝hf=10mm和6mm,所需焊缝长度为肢背:lw'0.65N0.65413991mm,取140mm.w2heff20.710200
肢尖:lw''0.3N0.3413991=86.248mm,取120mmef节点板上边缘缩进上弦肢背8mm,按构造要求取节点板用槽焊缝把上弦角钢和节点板连接起来。槽焊缝作为两条焊缝计算,需在强度设计值乘以0.8的折减系数。假定集中荷载P与上弦垂直,上弦肢背槽焊缝内的应力计算如下:
h'f等于二分之一节点板厚度,hf=110mm=5mm,h''f=10mm,上弦与节点板焊缝长度为460mm,则
fw111.72MPa
满足要求。上弦肢尖角焊缝的切应力为
fw32.56MPa
满足要求。
3).脊节点“G”
设拼接角钢与受压弦杆之间的角焊缝hf=10mm,则所需焊缝计算长度为(一条焊缝)
lw=65622240.710200117.835mm
拼接角钢长度ls2(lw2hf)+弦杆杆端空隙20,拼接角钢长度取400mm。
上弦与节点板之间的槽焊缝,假定承受节点荷载,验算如下
节点板长度为360mm,节点板的宽度为150mm,
上弦肢尖与节点板的连接焊缝,应按上弦内力的15%计算,
lw=(360/2-10-20)=150mm,焊缝应力为
Nτf0.15
×65622246.873MPa2×0.7×10×1506×0.15×656222×76.4Mσ143.244MPaf20.7101502126.42MPa
4).支座节点“A”
为了便于施焊,下弦杆角钢水平肢的底面与支座底板的净距离取160mm。在节点中
心线上设置加劲肋,加劲肋的高度与节点板高度相等,厚度12mm。
a.支座底板的计算。支座反力R=53822×8=431016N。
设支座地板的平面尺寸采用280×400mm,现仅考虑有加劲肋部分的底板承受支座反力,则承压面积为An=280×320=64960mm²。验算柱顶混凝土强度:
qR4310166.63MPa
2M=βqa1
式中,q为底板下的平均应力。a1
为两支撑边之间的对角线
a1173.4mmβ为系数,由b1/a1查表,b1为两支撑边的相交点到对角线a1的垂直距离。由相似
三角形的关系,得b2=85.0mm,b2/a2=0.49查表得β=0.0586
2M=βq
a10.05868.11173.42=14289.49Nm
底板厚度t16.63mm ,取t=20mmb.加劲肋与节点板的连接焊缝计算。假定加劲肋受力为屋架支座反力的1/4,即
431016/4=107754N,则焊缝内力为
V=107754N
M=107754×55=5826470N·mm
设焊缝hf=6mm,焊缝长度l
w=528-20-12=496mm,焊缝应力为
29.46MPa
其中每块加劲肋各R/4=107754N,节点板传递R/2=215508N。
节点板与底板的连接焊缝长度lw=2×(280-12)=536mm,所需焊脚尺寸为
hfR/22155082.354mm ,故取hf=wf6mm。
每块加劲肋于底板的连接焊缝长度为
l
hf=w=2×(110-20-12)=156mm所需焊缝尺寸为
一列出,见施工构造图。1077544.044mm ,故取hf=8mm。其他节点的计算不再一0.71562001.22
参考文献:
(1)《土木工程专业钢结构课程设计指南》,周俐俐、姚勇等编著,中国水利水电出版社、知识产权出版社,2006年1月第1版;
(2)《钢结构(上册)钢结构基础》,陈绍蕃、顾强主编,中国建筑工业出版社,2007年6月第二版;
(3)《建筑结构荷载规范》(GB50009-2001),中国建筑工业出版社,2006年11月第二版;
(4)《钢结构设计规范》(GB50017-2003),中国计划出版社,2003。
摘要:掌握钢屋架荷载的计算,杆件内力的计算和组合,杆件的计算长度、截面型式、截面选择及构造要求,填板的设置及节点板的厚度,普通钢屋架节点设计的原则和要求,主要节点的设计及计算和构造,以及钢屋架施工图的内容和绘制。设计成果应包括设计计算书(A4纸装订成册)和施工图纸1张;每个学生应认真独立完成全部设计任务,成果表面和技术质量符合工程设计文件的要求。作屋盖结构及支撑的布置图;对钢屋架进行内力、杆件截面尺寸的计算;设计一个下弦节点、一个上弦节点、屋脊节点、支座节点;绘制运输单元的施工图,设计的节点应尺寸齐备,满足构造要求。