垃圾填埋场防渗层渗漏检测方法的比较_王斌
第15卷 第5期
环 境 科 学 研 究Research of Environmental Sciences
Vol. 15, No. 5, 2002
垃圾填埋场防渗层渗漏检测方法的比较
王 斌, 王 琪, 董 路
1
2
2
(1.北京工商大学化学与环境工程学院, 北京 100037; 21中国环境科学研究院, 北京 100012)
摘要:对目前国外几种垃圾填埋场防渗层渗漏检测方法(地下水检测法, 扩散管法, 电容传感法, 追踪剂法, 电化学感应电缆法, 电学法) 进行了详细的叙述和比较, 并指出电学法是较好的检测方法。关键词:垃圾填埋场; 渗漏; 检测; 渗滤液; 电学法
中图分类号:X705 文献标识码:A 文章编号:1001-6929(2002) 05-0047-02
Comparison of Leakage Detection Methods for Landfill Liners
WANG Bin , WANG Qi , DONG Lu
1
2
2
(1. School of Chemical and Environmental Engineering, Beijing Technology and Business Universi ty, Beijing 100037, China;
2. Chinese Research Academy of Environ mental Sciences, Beijing 100012, China)
Abstract :The authors describe and compare in detail several main methods used in leakage detection for landfill liners, including ground water monitoring method, di ffusion hoses method, capacitance sensors method, tracers method, electro -chemical sensing cables method and electrical method, etc. It is indicated that the electrical method is better than other methods. Key words :landfill; leak; detection; leachate; electrical method 过去人们普遍认为垃圾及其渗滤液可以通过粘土和地下水得到降解(或净化) , 而不会污染地下水。从20世纪50年代开始, 西方国家一些机构的持续研究表明, 垃圾填埋确实污染地下水。因此, 填埋场防渗衬层系统就成了填埋场必不可少的设施之一, 其作用是将填埋场内外隔绝, 控制渗滤液进入粘土及地下水和阻止外界水进入填埋场增大渗滤液的产生量。这一系统的通用材料主要有粘土和人工合成材料, 人工合成材料最常用的是高密度聚乙烯(HDPE) 。防渗漏研究主要是以HDPE 的渗漏来展开的。1978年, 美国环境总署就指出所有的填埋场都会渗漏; 1990年美国一项最好填埋场衬层的监测表明, 在质量最好、费用最高的工程中, HDPE 的渗漏率是20L P (hm #d) , 该渗漏是由于制造时留下
2
[1]
1 几种主要的垃圾填埋场防渗漏检测方法
111 地下水监测法[3]
地下水监测法是利用检测填埋场的集水井中有无渗滤液来实现的。如果没有渗漏, 集水井中的水应是干净的地下水; 一旦发生渗漏并流到了地下水层, 就有可能在集水井中发现渗滤液。优点:利用填埋场自身的设施进行检测。缺点:由于集水井数量一般较少, 不能保证渗滤液一定会流入集水井, 如果增加集水井的数量, 工程费用又太高。112 扩散管法[4]
扩散管系统是将汽体透过性管路网络埋在衬层下的土壤中, 一个运转周期后, 由于渗滤液蒸汽进入管路, 可以通过抽出管内汽体、探测记录污染物浓度, 从而达到检测漏洞的目的。因为从漏洞扩散出的渗滤液蒸汽在土壤中按照一定的体积比例进入管内, 所以分析管内水蒸汽中污染物的浓度可以近似得到漏洞大小。优点:系统可自行运行, 操作费用少。缺点:如果渗滤液不产生蒸汽, 只有当渗滤液接触到管路才能检测到漏洞。113 电容传感器法[5]
电容传感器法是通过测量土壤绝缘常数的变化来检测渗漏。干土的绝缘常数在5左右, 水的绝缘常数在80左右, 当土壤因渗漏而变得潮湿, 绝缘常数会增加。测试一个区域
的针眼和施工时留下的小洞造成的。此外, 由于在填埋时产生的漏洞和HDPE 容许一些化学物质通过(如:甲苯, 二甲苯, 二氯甲烷, 三氯乙烷等)
[2]
[2]
, 渗漏率会更大, 对地下水的污
染也就更大。因此, 为了防止地下水污染, 垃圾填埋场防渗漏检测的研究也就格外重要了。
国外防渗漏检测的研究始于20世纪70年代末, 应用始于80年代, 而国内的研究才刚刚起步。
收稿日期:2002-03-28
作者简介:王斌(1977-) , 男, 陕西榆林人, 硕士研究生1
土壤绝缘常数的变化可知是否有漏洞出现。电容传感器是,
周围土壤绝缘常数在某一个谐波频率下共振, 根据得到的频率, 由校准曲线可确定湿度。优点:已有电容传感器成品, 不需要另行研制。缺点:通过电容传感器测到的湿度并非专为渗滤液的湿度。114 示踪剂法[6]
示踪剂法是将采样收集探针插入填埋场周边近地面的土壤中, 并把一种挥发的化学示踪剂注入垃圾填埋坑中, 如果探针检测到示踪剂, 则表明有漏洞。优点:可用于任何填埋物和填埋场任何阶段的检测。缺点:大多数示踪系统不能发现漏洞位置, 只能确定是否存在漏洞。另外, 系统自动收集、分析样品的技术还未成熟, 一些系统需要技术人员对土壤气体进行人工收集和分析。115 电化学感应电缆法
[7]
所绘制的电压分配图, 可以判断漏洞的位置和数量。该法适用于在没填垃圾前的衬层施工验收。11612 电极格栅法[9]
电极格栅法是利用渗滤液比地下水有更好的导电性来实现的。施工时在土工膜下安装电极格栅(用导线做的格栅, 每根导线上都按一定的距离有若干电极) , 当有渗漏发生时, 被渗滤液浸湿的电极显示出比没有被浸湿的电极较高的电压, 有较多渗滤液的地区比渗滤液较少地区的电压高。根据绘制的电压分配图可以判断漏洞的位置、大小和数量。优点:组件简单、耐用, 可监测衬层下的完整区域。缺点:不适用于已建好的垃圾填埋场, 因为电极格栅必须在施工时放入填埋单元。
2 结论
以上几种方法的综合比较见表1。
表1 几种主要检测方法的比较
Table 1 Comparison of several main methods used
in leakage detection
方法地下水检测法扩散管法电容传感法示踪剂法
电化学感应电缆法双电极法电极格栅法
任何时候确定渗确定漏能否广能否重自动化都可安装漏位置洞大小泛应用复使用不可以不可以不可以可以不可以可以不可以
不能能能不能部分不能能
不能能不能不能不能不能能
能不能能能能不能能
能能不能能部分能能
程度没有有没有没有有没有有
电化学感应电缆法主要是利用目标污染物引起了感应电缆的物理和化学变化, 这些变化引起或干扰光电信号, 通过测量由于与污染物接触导致的电压降来检测渗漏。优点:特别适用于检测含有碳氢化合物的填埋场。电缆发生的反应大多数是可逆的, 所以电缆可以利用可逆反应再生而不需要在出现渗漏后被替换。缺点:电缆只能检测一个狭窄范围的污染物。每个填埋场必须安装特殊的电缆来检测产生渗滤液的不同成分。116 电学法11611 双电极法[8]
双电极法是利用渗滤液或地下水的导电性和HDPE 的绝缘性来实现的。在填埋坑中放置一个发射电极, 在填埋坑以外的近地面的土壤中放置一个接受电极。当土工膜没有漏洞时, 给两个电极加一定的电压, 不能形成回路, 无电流; 当有漏洞时, 电流就可以把渗滤液或地下水作为导体穿过漏洞从而形成回路, 显示一定的电流值。优点:不需要预先在衬层下安装任何传感器。缺点:只能检测到有无漏洞, 不能检测到漏洞的大小、位置和数量。
美国学者Shultz O. W. [9]研究的电极-偶极子法(改良的双电极法) 如图1所示:在填埋场外放一回流电极, 场内放一发生电极和一移动检测电极对(偶极子) 。给发生电极和回
由以上的比较和国外的一些评述[10], 可以得出电学法(许多情况下是将双电极法和电极格栅法结合使用) 是较好的一种。电学法的原理易懂, 组件简单且耐用, 适用范围也较广。在美国内华达州的Elko 金矿, 电学法渗漏检测已使用了17a 。1995年在英国兴建的Sandy Lane 垃圾填埋场也用了电学检测法, 效果不错。
参考文献:
[1] 国家环境保护总局污染控制司. 城市固体废弃物管理与处理
处置技术[M]. 北京:中国石化出版社, 2000.
[2] Rudolph Bonaparte, Beth A Gros s. Fi eld behavior of double -liner sys -te ms[A]. Rudolph Bonaparte. Was te containment sys tems:cons truc -tio n , regulation and performance [C]. New York:American s ociety of civil engineers, 1990. 52-83.
[3] Godfrey K A. Monitoring for haz ardous waste leaks[J]. Ci vil Engi neer -i ng, 1987, 57:48-49.
[4] Stammler M , Bol J. Eval uati on of me thods for monitoring landfill barr-i
ers[EB P O L]. http:P P clu -in. org P charl. cfm. 2001-10-10.
[5] Vendor F ACTS 3. 0. EPA . s field analytical and charac terization tech -nology s ys tem database[EB P OL]. http:P P clu -in. org P charl. cfm. 1997-12-02.
图1 电极-偶极子法示意图
Fig. 1 The scheme of pole -dipole electrical detection 流电极加一电压, 当衬层有漏洞时, 移动检测电极两端就会有一定的电压显示。通过由移动检测电极测得的电压数据
(54)
性。De Baere [19]通过对欧洲固体垃圾厌氧消化的调查发现, 两相消化所占的比重比单相消化要小得多, 原因是两相消化系统需要更多的投资, 以及运转维护也更为复杂。
crop residues[J]. Agricul tural Wastes, 1981, (3) :179-189.
[7] Zhang Ruihong, Zhang Zhiqin. Biogasification of rice s traw with an
anaerobic -phased s olids diges ter system[J]. Bioresource Technology, 1999, 68:235-245.
[8] 伍义泽. 沼气干发酵工艺必需的条件:沼气新技术应用研究
[M]. 成都:四川科学技术出版社, 1988. 47-58.
[9] Walter J Wujci k. Anaerobic dry fermentati on [J ]. Biotechnology &
Bioengineeri ng Symp, 1980, (10) :43-65.
[10] Liss ens G, Vandevivere P, De Baere L, et al. Solid was te digester:pro -ces s performance and practice for municipal solid was te digestion[J]. Water Sci Tec h, 2001, 44(8) :91-102.
[11] Palmows ki L M , M ller J A. Influence of the size reducti on of organic
waste on their anaerobic di ges tion[J]. Water Sci Tech, 2000, 41(3) :155-162.
[12] Ghos h S , Henry M P, Sajjad A, et al. Pilo-t scale gasificati on of munic -ipal solid wastes by high -rate and t wo -phase anaerobic digestion (TPAD) [J]. Water Sci Tech, 2000, 41(3):101-110.
[13] Hasegawa S, Shi ota N, Katsura K, et al. Solubi li zati on of organic
sludge by thermophilic aerobic bacteria as a pretreatment for anaerobic digestion[J]. Water Sci Tech, 2000, 41(3):163-169.
[14] Kubler H. Full scale co -di ges tion of organic waste [J ]. Water Sci
Tech, 2000, 41(3) :263-274.
[15] 孙国朝, 邵廷杰, 郭学敏. 沼气干发酵工艺必须的条件:沼气新
技术应用研究[M]. 成都:四川科学技术出版社, 1988. 47-58. [16] 张光明, 王伟. 厌氧消化处理生活垃圾工艺研究[J ]. 中国沼
气, 1997, 15(2):14-16.
[17] Ghosh S. Gas produc tion by accelerated bioleachi ng of organic mater-i
als[P].U S Patent:4, 396, 402, 1983-08-02.
[18] Ghosh S , Buoy K, Dres sell L, et al. Pilo-t and ful-l scall two -phase
anaerobic diges ti on of munici pal slurge[J ]. Wat Environ Res, 1995, 67(2):206-214.
[19] De Baere L. Anaerobic digestion of s olid was te:state -the -art[J]. Wa -ter Sci Tech, 2000, 41:283-290.
[20] 陈洪章, 陈继贞, 李佐虎. 麦草汽爆工艺的研究[J ].纤维素科
学与技术, 1999, 7(2) :60-64.
[21] 陈洪章. 纤维质原料微生物转化与生物量全利用的研究[D].
北京:中国科学院化工冶金研究所. 1998. 40-69.
4 结语
根据现有的研究发现, 固态厌氧消化的速度都很慢, 需要在对固体废物的预处理方法以及消化工艺等方面进行完善和改进。
由于有机固体废物中含有大量的纤维素、木质素等难降解的成分, 利用汽爆技术有望加速纤维素等难降解成分的降解。汽爆过程中, 废物处在高温高压的蒸汽条件下, 然后瞬间蒸汽和废物急速膨胀。汽爆过的秸秆其纤维素本身的结晶结构发生改变以及半纤维素和木质素对纤维素降解所起的阻碍和屏障作用受到破坏[20]。可以预想, 这样的预处理措施能加速纤维素的降解, 从而提高厌氧消化的效率。
由于固态厌氧消化中, 通过外部刺激能加强消化过程中的传质、传热、传动以及信息传递作用[21]。在固态厌氧消化过程中, 可以通过压力脉动这种外部刺激技术来加速消化速度, 提高沼气产率。压力脉动就是在反应过程中气体压力逐渐升高到一定程度, 然后迅速降低压力, 如此反复。在这里, 压力脉动起到了搅拌的作用, 这样就克服了在总固体含量过高的情况下难以搅拌的困难。
参考文献:
[1] 蔡振明, 高爱忠, 祁梦兰. 固体废物的处理与处置[M]. 北京:
高等教育出版社, 1993. 248-250.
[2] Liu Tuanchi, Sambhunath Ghos h. Phas e separati on duri ng anaerobic
fermentation of solid s ubs trates in innovative plug -flow reactor [J ]. Water Sci Tech, 1997, 36(6P 7) :303-310.
[3] 赵秦生, 胡海南. 新材料与新能源[M]. 北京:轻工业出版社,
1987. 425-455.
[4] 刘金鑫, 孙国朝. 沼气发酵微生物代谢的相互关联初探:沼气
新技术应用研究[M]. 成都:四川科学技术出版社, 1988. 253-268.
[5] Sain-t Joly C, Desbois S, Lotti J P. Determinant i mpact of was te co-l
lection and composition on anaerobic diges ti on performance:industrial res ults[J]. Water Sci Tech, 2000, 41(3) :291-297.
[6] Hills D J, Roberts D W. Anaerobic digestion of dai ry manure and field
(上接第48页)
[6] Williams C V, Dunn S D, Lowry W E. Tracer veri fication and monitor -ing of containment systems(Ò) [A]. Proceedi ngs of the Internati onal Containment Technology Conference[C]. St Peters burg Flori da:[sn], 1997. 1039-1045.
[7] Rumer Ralph R, Mitc hell, J ames K. Ass essment of barrier containment
technologies[A]. International containment technol ogy works hop[C]. Baltimore Maryland:[s n], 1995. 355-394.
[8] White C C, Barker R D. Electrical leak detec tion s ys tem for landfill
liners:a case history[J]. Ground Water Moni tor Remediati on, 1997, 17(3) :153-159.
[9] Parra J O. Electrical response of a leak in a geome mbrane liner[J].
Geophysics, 1988, 53(11):1445-1452.
[10] Jordan Co. Performance standard for evaluating leak detecti on [R].
US:Environmental Protection Agency, Contrac t no. 68-01-6871. 1984.