超长预应力抗拔桩施工技术
超长预应力抗拔桩施工技术
摘要:为解决地下室的抗浮问题,近年来抗拔桩的应用已经越来越普遍。我国自2002年起也在各个工程中逐步开始应用,相关技术研究也逐渐成熟。而本工程的抗拔桩设计桩长达50m ,其预应力筋必须通长连续配置,对施工工艺提出了非常高的要求。本文根据工程实践,探索了超长抗拔桩预应力与灌注桩同步施工的工艺技术,积累了一定的施工经验,可供类似工程参考。
关键词:抗拔桩;无粘结预应力;钻孔灌注桩
Abstract: In order tosolve the problemoffloatingin the basement,in recent years theapplication ofuplift pile has been more and morewidely.Chinasince 2002in variousengineeringgradually began to use,research relatedtechnology also graduallymature.The engineeringdesign of uplift pilepileup to50m,the prestressed reinforcementmust belongcontinuous configuration,put forwardvery highrequirements for construction technology.According to theengineering practice,explores theprocesstechnology of super-long pileof prestressed concrete andcast-in-place pile synchronous construction,accumulated acertain construction experience,for reference to similar engineering.
Keywords:uplift pile;unbonded prestressed;bored pile
前言
为解决地下室的抗浮问题,近年来抗拔桩的应用已经越来越普遍。根据抗拔桩的受力机理,将后张法预应力技术应用于抗拔桩显得极其自然,于是国内自2002年起也在各个工程中逐步开始应用,相关技术研究也逐渐成熟。配置预应力筋的抗拔桩的主要优点是:第一,提高桩体力学性质。通过预先埋设在桩体内的预应力钢绞线给桩施加预应力,使桩体在受拉的过程中而桩内部处于受压状态。第二,改变受力路径。通过预留钢绞线自由段的方式使得上拔力着力点在桩的下部,从而使桩侧土摩阻力从下至上随荷载的增大而逐渐发挥。第三,提高抗拔承载能力。在不改变桩身截面形状的情况下也可以最大限度的提高桩的抗拔承载力。第四,节约成本。从结构的角度而言,预应力高强钢绞线使用在抗拔桩上,可以有效地提高桩的刚度,减少配筋数量,减小桩结构尺寸,从而节省大量投资。预应力抗拔桩抗裂性能、经济性好,是抗拔桩的最佳形式,必将广泛应用于工程中。
一、工程概况
该工程的抗拔桩采用钻孔灌注桩,桩身直径800mm ,桩长约50m ,普通钢筋10φ18,预应力筋14Uφs15.2 。预应力筋桩截面环向双根均布,置于φ14@2000的加劲环筋内侧并与之绑扎固定。如下图所示。